MacDon M200 Operator's Manual Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 234
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
HEADER OPERATION - D SERIES
Form 169017 / 169087 / 169095 98 Revision C
Example:
Windrower is operating at 8 mph with Header
Index “on” and set at 1.5. Display shows;
9.5 1.5 DRAP INDX
where 9.5 (8+1.5) is the draper speed in mph,
and 1.5 is the header index setting.
Windrower speed drops to 7.5 mph at same
Header Index setting. Display shows;
9.0 1.5 DRAP INDX
where 9.0 (7.5+1.5) is the draper speed in mph,
and 1.5 is the header index setting.
Windrower is operating at 8 mph with Header
Index “on” and set at 0.9. Display shows;
8.9 0.9 DRAP INDX
where 8.9 (8+0.9) is the draper speed in mph,
and 0.9 is the header index setting.
6.5.7.2 Draper Speed Independent of Ground
Speed
Set the speed of the draper independently of
ground speed as follows:
NOTE
This procedure can also be used to change
the draper speed “on the go”.
CAUTION
Check to be sure all bystanders have cleared
the area.
##.# = MPH or KPH
HEADER ENGAGED
ON CDM PRESS
FAST OR SLOW
DISPLAY SHOWS
##.# DRAPER SPEED
DONE
SPEED
O.K.?
NO
YES
PRESS DISPLAY SELECTOR
FOR DRAPER SPEED
HEADER INDEX
SWITCH - OFF
Page view 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 233 234

Comments to this Manuals

No comments